AN IMPROVED FOPID-CONTROLLED HYBRID TRANSFORMER-LESS SINGLE-PHASE GRID-CONNECTED SOLAR PV INVERTER WITH REACTIVE POWER COMPENSATION AND LEAKAGE CURRENT MITIGATION
DOI:
https://doi.org/10.62643/ijerst.2026.v22.n4.4864Abstract
This work presents a FOPID-controlled hybrid transformer-less single-phase grid-connected photovoltaic (PV) inverter designed to mitigate leakage current while enabling reactive power compensation. Conventional transformerless inverters offer high efficiency and reduced cost but suffer from leakage current issues due to the absence of galvanic isolation, leading to safety concerns and power quality degradation. To address these challenges, a hybrid inverter topology combining DC decoupling, AC decoupling, and mid-point clamping techniques is proposed to suppress common-mode voltage variations effectively. The system employs a Fractional Order Proportional-IntegralDerivative (FOPID) controller to enhance dynamic response, improve tracking accuracy, and ensure robust performance under varying operating conditions such as irradiance fluctuations and load disturbances. The proposed control strategy enables independent regulation of active and reactive power, thereby supporting grid voltage stability and power factor correction. The performance of the system is validated using MATLAB/Simulink simulations under both open-loop and closed-loop conditions. Comparative analysis with conventional model predictive control (MPC) demonstrates significant improvements in leakage current suppression, reduced total harmonic distortion (THD), faster transient response, and enhanced stability. The proposed inverter thus provides an efficient, reliable, and gridcompliant solution for modern distributed PV systems.
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.