DESIGN AND ANALYSIS OF G+12 WITH AND WITHOUT FLOATING COLUMNS
Keywords:
Floating Columns, Staad Pro, Bending Moment, Shear Force, Sesimic Zone, Shear PannelAbstract
In present scenario buildings with floating column is a typical feature in the modern multistorey construction in urban India. Such features are highly undesirable in building built in
seismically active areas. This study highlights the importance of explicitly recognizing the
presence of the floating column in the analysis of g+12 building. Alternate measures, involving
stiffness balance of the first storey and the storey above, are proposed to reduce the irregularity
introduced by the floating columns. The component backbone modelling for the concrete columns
also had to change so that convergence could be reached in the STAAD PRO and the Perform-3D
models. To prevent a backbone with negative stiffness, a conservative backbone was used, in
which the nominal capacity was taken at the onset of steel yielding, and then a line was drawn to
the peak moment capacity. At this point, the column was assumed to have lost any significant
capacity Because the rotational demand was relatively small for the columns in this project, this
ultimate point of rotation was never reached FEM codes are developed for 2D multi storey frames
with and without floating column to study the responses of the structure under different earthquake
excitation having different frequency content keeping the PGA and time duration factor constant.
The time history of floor displacement, inter storey drift, base shear, overturning moment are
computed for both the frames with and without floating column.