Upgrading the 31-Level Distribution Network Through Integration of Advanced Lower DC Voltage Sources
Keywords:
Total harmonic distortion, Total Sequence Voltage, Total Sequence Voltage Calculation, and Cost Function (CF) in Multilevel Inverters (THD)Abstract
In this research, we propose a novel topology for a 31-level asymmetrical multilevel inverter optimized for singlephase operation, boasting a streamlined design with fewer components compared to existing configurations.
Leveraging an H-bridge configuration in conjunction with asymmetric DC sources, this innovative topology enables
the generation of an output voltage with up to 31 distinct levels. Initially conceived as an extension of the
fundamental 13-level multilevel inverter (MLI) architecture, our study delves deeper into refining the topology to
accommodate 31 levels, catering to the burgeoning demand for renewable energy applications.
Through meticulous design refinement, our approach significantly reduces system size, cost, and the
number of individual components, thereby enhancing overall system efficiency and affordability. Despite the
numerous advantages offered by MLIs, reliability remains a persistent challenge due to the additional components
required to mitigate total harmonic distortion (THD). Addressing this concern, our research endeavors to strike a
balance between enhancing reliability and minimizing THD levels, a formidable task that has eluded many
researchers.
Key performance metrics including total standing voltage (TSV), cost function (CF), and power loss are
comprehensively analyzed for both the foundational 13-level and the advanced 31-level MLIs. Rigorous laboratory
testing under diverse dynamic load conditions, encompassing various combinational loads and unexpected load
disturbances, validates the efficacy of the proposed MLI architecture.
Comparative analyses against previously published topologies highlight the cost-effectiveness of our
proposed MLI, showcasing reduced TSV requirements and component count. Moreover, THD levels achieved
comfortably comply with IEEE standards, underscoring the robustness of the architecture.
Theoretical validation through MATLAB/Simulink simulations is seamlessly complemented by empirical
testing utilizing a hardware prototype across a spectrum of real-world scenarios, reaffirming the viability and