Improving the efficiency of isolated-footingresting on loose sand soil using grout diaphragm walls: an experimental and numerical study
Keywords:
Grout, Bearing capacity, Settlement, Circular footing, Improved soilAbstract
Increases in live loads, eccentric loads, and the number of floors a building has all contribute to the increasing pressures
placed on foundations. The solution to this problem is to increase the bearing capacity of the loose-dense sand subgrade by
placing horizontal reinforcements under the footings. In addition to reducing soil movement in the horizontal direction
beneath the selected loaded footing, grouting on both sides of the footing minimises vertical settlement. A circular foundation
sitting on granular soil injected with grout diaphragm walls will be evaluated for efficiency in this research via comprehens ive
experimental work on twenty-one (21) soil models. In particular, the relation between the width (b) and length (L) of grouted
walls and the bearing capacity of granular soil was examined in this work. Adding grouted wall injection on either side of the
current footing is a great way to increase the subgrade layer's bearing capacity, according to the findings. Both the 3D PLAX IS
program and the 2D Finite Element Program GeoStudio 2018 were used to verify the accuracy of the selected computational
procedures. The results show that the experimental findings are directly correlated with the fact that the reinforcement
significantly affects the bearing capacity of a circular footing on granular soil.
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.